HTS1000 High Temperature Dielectric Measurement System — 1

Overview

The HTS1000 High Temperature Dielectric Measurement System by MatMeas is a laboratory and production-grade platform designed for accurate dielectric property testing under high-temperature conditions. It can precisely measure dielectric performance, impedance characteristics and resistive behavior by changing fixtures for different testing requirements. With a temperature range from room temperature to 1000°C, stable PID temperature control, and selectable atmospheres including air, flowing gas and vacuum, the system helps universities, research institutes and industrial laboratories perform reliable material characterization in ceramics, semiconductors, energy materials, chemical materials and electronic materials.

Specifications

Parameter Value
Temperature Range RT–1000°C
Temperature Accuracy ±1°C
Heating Rate 0–10°C/min (Typical 3°C/min)
Heating Method Resistance wire heating
Frequency Range 10 Hz–10 MHz
Measurement Atmosphere Air / Flowing Gas / Vacuum
Recommended Sample Size D = 8–12 mm, t = 1 mm
Electrode Material 2520 Stainless Steel
System Dimensions (L×W×H) 520 × 320 × 716 mm
Power Supply 220V / 50Hz–60Hz
Power Consumption 1600 W
Weight 46 kg
Warranty 1 year

Applications

  1. Dielectric property analysis of ceramics and electronic materials
  2. High-temperature characterization of semiconductor materials
  3. Research on energy storage and functional materials
  4. Impedance and resistivity testing in materials science laboratories
  5. R&D applications in chemical, aerospace and biomedical materials

More Details

  1. HTS1000 Dielectric Tester Features
    The HTS1000 supports multi-environment measurement and can be upgraded from air atmosphere to flowing gas and vacuum atmosphere. Optional multi-channel gas charging devices enable manual or automatic gas distribution for flexible laboratory testing.
  2. HTS1000 Precision & Calibration
    Factory calibration, automatic open/short and high-frequency load compensation, and the introduced 4W measurement method improve measurement accuracy for high-resistance and low-capacitance components.
  3. HTS1000 Fixture & Temperature Control
    The upgraded fixture uses high-quality ceramic materials with high-temperature oxidation resistance and low contact resistance. Precise sample pressure control helps reduce data jumping, while the furnace-lifting design and optimized thermal field improve temperature precision and contact stability.